Printed from Kezuriba (kezuriba.net/en/nc/g82/)
G82
Machining centerModal, group 09Drilling cycle (counter boring, dwell at hole bottom)
Format and notes
G82 X_ Y_ Z_ R_ P_ (dwell) F_ K_
- G81 plus a dwell at the hole bottom. Gives a clean bottom face when spot facing or chamfering
- The unit of P differs by machine (the Siemens ISO example uses P1000 with no decimal point; NIST and Haas use seconds)
Diagram: G82 motion (side view)
Full guide with examples: Canned cycles: how each one moves, how to choose, G98 vs G99
Try it in the simulator (machining center)
G85 feeds out (reaming/boring), G86 stops the spindle and rapids out, G82 dwells at the bottom.
X—
Y—
Z—
T—
S0
F0
—0:00
Simulator with exercises: Machining center page
Frequently asked questions about G82
- What is G82 (Drilling cycle (counter boring, dwell at hole bottom)) used for and how is it formatted in a CNC program?
- G82 commands "Drilling cycle (counter boring, dwell at hole bottom)" on Machining center. The standard program format is "G82 X_ Y_ Z_ R_ P_ (dwell) F_ K_". G81 plus a dwell at the hole bottom. Gives a clean bottom face when spot facing or chamfering
- Is G82 a modal code or a one-shot (non-modal) code?
- G82 is a modal code (Group 09). Once commanded, it remains active across subsequent blocks until another code from the same modal group overrides it or the control is reset. Always state or cancel modal states explicitly in your safety block and at the end of a tool operation so residual modes do not cause unexpected motion when restarting mid-program.
- Does G82 work differently on machining centers (mills) versus CNC lathes?
- G82 is primarily used on Machining center. Depending on the machine type and the lathe G-code system (System A, B, or C), this code may be unavailable or assigned to a different function, so verify against your machine tool manual.
- Are there differences in G82 across FANUC, Mitsubishi, Okuma, Haas, and Siemens controls?
- While the core behavior of G82 is shared across most ISO-compatible CNC controls (FANUC, Mitsubishi Electric, Haas), controls using native conversational or proprietary dialects (such as Okuma OSP, Siemens native mode, or Heidenhain) or machine-specific M-code tables may use different syntax. Always verify with single-block execution and distance-to-go display on a new machine.
Sources
The meaning of this code agrees in two or more sources from different publishers. Explanations are written in our own words.
- Siemens AG — SINUMERIK 802D sl/840D/840D sl/840Di/840Di sl/810D Programming Manual ISO Milling, 04.2007 Edition (6FC5398-7BP10-0BA0) cache.industry.siemens.com
- Haas Automation, Inc. — Mill Operator's Manual – 17 Mill G-Codes (online version) haascnc.com
- National Institute of Standards and Technology (NIST), USA — The NIST RS274NGC Interpreter – Version 3 (NISTIR 6556, 2000) nvlpubs.nist.gov