GAUGESInspection Instruments and Measuring Tools Database

A summary of how to read the scale, correct use, common measurement mistakes, and care and inspection for 25 measuring tools used on the shop floor. For calipers, micrometers and dial indicators, you can practice reading with diagrams.

Set it on right,
and read the scale
straight on!

Chips, the Kezuriba mascot

Measurement error basics

These are 3 reasons readings drift that apply to every measuring instrument, and how to decide pass/fail. For details, see the article "Measurement error basics", which comes with calculators.

Measuring length

Caliper

Vernier caliper / Calliper

The most familiar measuring tool: one instrument measures outside, inside, step, and depth

Outside micrometer

Outside micrometer

Measures outside diameter and thickness to 0.01 mm (0.001 mm for digital) by feeding a screw

Inside micrometer

Inside micrometer

A micrometer that measures hole inside diameters and groove widths with jaws or rods

Three-point inside micrometer (bore micrometer)

Three-point internal micrometer (bore micrometer)

Three contact points touch the inner surface of the hole and self-center on the hole's axis to measure the inside diameter

Depth gauge

Depth gauge (vernier / dial / digital)

A caliper-type tool that measures the depth of holes and steps with its base held against the workpiece

Depth micrometer

Depth micrometer

Measures the depth of holes and steps with micrometer accuracy, with the base held against the workpiece

Height gauge

Height gauge

Measures height on a surface plate and can also scribe layout lines

Measuring by comparison

Dial indicator (plunger type)

Dial indicator / Mechanical dial gauge

Magnifies spindle movement with a pointer to compare and measure runout, flatness, and height differences

Lever-type dial indicator (dial test indicator)

Dial test indicator (lever type)

A dial test indicator with a lever-type contact point, for measuring runout and centering in tight spaces

Cylinder gauge

Bore gauge / Cylinder gauge

Set zero on a master, then read the difference in the hole's inside diameter on the indicator

Feeler gauge

Feeler gauge

Insert thin leaves of different thicknesses to check the size of a gap

Radius gauge

Radius gauge

Held against a corner or fillet to check the size of the radius (R)

Length standards

Gauge block

Gauge block (gage block)

Blocks that serve as the length reference; wrung together to build any length

Limit gauge

Pin gauge

Pin gauge (plug gauge pin)

Insert a pin of known diameter into a hole and check the hole diameter by whether it goes through

Limit plain gauges (plug gauge, ring gauge, snap gauge)

Plain limit gauge (plug / ring / snap gauge)

Judges with a go side and a no-go side whether a hole or shaft is within tolerance

Threads and gears

Thread limit gauges

Thread limit gauge (GO/NOT GO thread plug & ring gauge)

Judges whether an internal or external thread passes, using the go and no-go sides of the thread gauge

Pitch gauge (thread pitch gauge)

Screw pitch gauge

Held against a thread to check the thread pitch (threads per inch)

Gear tooth micrometer

Gear tooth micrometer (disc micrometer)

Measures the span (base tangent) tooth thickness of gears with disc-shaped measuring faces

Over-pin (over-ball) measurement

Over-pin / over-ball measurement

Place pins (balls) in the tooth spaces and measure the outside to find the tooth thickness

Angles and flatness

Surface plate

Surface plate

A flat table used as the reference for measuring and layout

V-block

V-block (Vee block)

Supports a round workpiece in the V-groove to measure runout and center

Precision square

Square (engineer's square)

A 90° reference. Checks the squareness of workpieces and fixtures

Precision level

Precision level (spirit level)

Measures slight tilt of machines or surface plates from the position of the bubble

Surface and form

Surface roughness tester (stylus type)

Surface roughness tester (stylus type)

Traces the surface with a stylus to measure roughness such as Ra and Rz

Coordinate measuring machine (CMM)

Coordinate measuring machine (CMM)

Moves the probe in 3 directions to measure size, form, and position from coordinates

Frequently Asked Questions

Why is 20 °C the reference temperature for measurement?
Because drawing dimensions are values at 20 °C (ISO 1). For example, measuring 100 mm of aluminum with a caliper, both at 25 °C, reads about 7 µm large. You can estimate this with the thermal expansion calculator.
How can I reduce error when measuring with a vernier caliper?
A caliper does not follow Abbe’s principle because its scale and the measuring point are apart, so the further from the scale you measure, the larger the error. Hold the part near the base of the jaws.
Does measuring force change the reading?
Yes. A 10 mm steel ball is squashed by about 1 µm even at 5 N and reads small. Use the ratchet on a micrometer and an even force on a caliper so every measurement is taken the same way.
Can a reading right at the tolerance limit be accepted?
A reading right at the edge of the tolerance cannot be called a pass with certainty. Decide conformity with the measurement uncertainty included (JIS B 0641-1). Our article on measurement error basics has a guard band calculator.