Air compressor troubleshooting chart
Look up likely causes, what to check, and remedies from the symptom. Your machine's instruction manual always takes priority for inspection and replacement intervals and oil types. The intervals here are examples for models found in public documents and vary with running hours, ambient temperature, and dust. Never remove a safety valve or raise its setting. Leave dryer refrigerant, disassembly and overhaul of the main unit, and electrical work to the manufacturer, a dealer, or qualified personnel. The key points of the laws were checked on e-Gov on 2026-10-06
Insufficient discharge volume or pressure (pressure does not rise as usual)Common
Consumption on the user side, intake filter, piping leaks, pressure gauge and pressure switch settings[1][7]
| Likely cause | What to check | Action |
|---|---|---|
| Air consumption exceeds the discharge volume (including air leaks) | Leak rate with the ends closed; air required by the connected equipment | Fix the leaks. If that is still not enough, consider adding or replacing a compressor[1][2] |
| Clogged intake filter | Dirty filter | Clean or replace it[1][3][4] |
| Solenoid valve fault, intake valve not opening fully, clogged separator element (screw) | Load/unload switching; separator replacement interval | Replace the solenoid valve. Replace the oil, oil filter, and separator. Have the manufacturer inspect the intake valve[1](1 source, for reference) |
| Worn piston rings or valves (reciprocating) | Whether the tank fill time has lengthened; piston ring thickness | Replace when the wear limit is reached (ask the dealer or manufacturer)[5][6] |
High discharge or unit temperature, or shutdown on abnormal temperatureCommon
Room temperature and ventilation, dirty cooler, oil level[1][3]
| Likely cause | What to check | Action |
|---|---|---|
| Insufficient cooling air (poor ventilation, recirculating exhaust) | Compressor room temperature; blocked intake and exhaust openings; exhaust duct | Improve ventilation and keep the cooling air from recirculating[1][8][9] |
| Dirty oil cooler or air cooler | Dust on the fins | Clean the fins. For clogging inside the cooler, ask the manufacturer[1][3] |
| Low oil level | Oil level gauge | Top up with genuine oil[1][10] |
| Deteriorated oil, clogged oil filter, faulty temperature control valve | Oil and filter replacement intervals | Replace according to the replacement guide[3](1 source, for reference) |
| Water-cooled: cooling water too hot, insufficient water flow, scale in the water circuit | Cooling water temperature and flow | Increase the water flow and clean the water circuit and cooler[1](1 source, for reference) |
Water appears in downstream piping and equipmentCommon
Auto drain discharge, dryer alarm and dew point, tank drain[3][1]
| Likely cause | What to check | Action |
|---|---|---|
| Clogged or faulty auto drain (drain trap) | Whether condensate is coming out; the filter and float valve | Disassemble and clean, and replace if necessary[3][1] |
| High dryer dew point (high intake or ambient temperature, exceeding capacity, low refrigerant, dirty air cooler) | Dryer inlet temperature, room temperature, throughput | Bring temperature and throughput within specifications. Leave the refrigerant to the manufacturer[1][3] |
| Air tank has not been drained | Tank drain valve | Drain it every day. Fit an auto drain[11][7] |
High oil consumption, or oil in the compressed airScrew
Safety valve blows under load; does not unloadScrew
Discharge pressure setting, safety valve set value[1]
| Likely cause | What to check | Action |
|---|---|---|
| Fault in the safety valve, intake valve, or minimum pressure valve, or a failed solenoid valve | Pressure set values | Replace the solenoid valve. Have the manufacturer inspect the valves[1](1 source, for reference) |
| Clogged oil separator element | Replacement interval | Replace the oil, oil filter, and separator[1][3] |
| Blockage from frozen dryer piping | Refrigerant circuit; dryer intake and exhaust conditions | Have the manufacturer inspect the refrigerant circuit. Do not attach an intake duct to the dryer exhaust port[1][9] |
Burning smell, discharge piping abnormally hot (sign of ignition from carbon deposits)Common
| Likely cause | What to check | Action |
|---|---|---|
| Carbon deposits from the lubricating oil built up in the separator and piping, and reaction heat accumulated | Oil replacement interval; the oil in use (genuine or not); the inside of the piping | Stop immediately and have the manufacturer inspect it. Use genuine oil and keep to the replacement intervalsIf it gets worse it ignites and, in the worst case, explodes (JSIM)[7][10] |
Will not start, or stops while running (overload)Common
Power supply and breaker; overload relay indication[1][8]
| Likely cause | What to check | Action |
|---|---|---|
| Motor overload relay or thermistor tripped, wrong phase sequence, broken wiring | Controller display; phase sequence | Reset an overload only once; if it recurs, contact the manufacturer[1](1 source, for reference) |
| Insufficient power supply capacity, voltage drop, phase imbalance | Breaker capacity; voltage drop at start-up | Use a breaker of sufficient capacity. Keep temporary voltage drops within −10 %. If voltage fluctuation or phase imbalance is large, install an AC reactor on the power supply side[8](1 source, for reference) |
Air tank ruptured (lessons from accident cases)Common
| Likely cause | What to check | Action |
|---|---|---|
| Pressure above the tank's strength was applied because the safety valve was removed or poorly maintained, or the pressure regulator failed | Safety valve operation; pressure switch operation; the tank's inspection stamp and specification sheet | Use a tank that passed inspection, and inspect the safety valve and pressure regulator regularly. Never remove a safety valve or raise its setting[12][13](1 source, for reference) |
| A tank built in-house without strength calculations (it is a Class 2 pressure vessel but did not go through the structural standard or inspection) | Whether any tank has been built or modified in-house | Even for a tank used within your own company, if it falls under Class 2 pressure vessels, use one built to the structural standard that has passed individual inspection[14][13](1 source, for reference) |
Causes on the side of machining conditions and tools are covered in the Machining Troubleshooting Encyclopedia .
📚Sources
Items without a mark are those on which two or more materials from different publishers agree. Values and intervals are governed by each machine's specifications. The text is summarized in Kezuriba's own words.
- Atlas Copco, "How to troubleshoot air compressors"
- Organization for Small & Medium Enterprises and Regional Innovation, Japan (SMRJ), J-Net21, Energy-saving Q&A, "What is the energy-saving effect of compressed air leak countermeasures?"
- ANEST IWATA, "Roles of parts and their faults (screw compressors)" (LRS-220BD periodic inspection and maintenance reference table)
- Japan Industrial Machinery Manufacturers Association (JSIM), General-Purpose Compressor Committee, “Pamphlet ‘Maintenance Recommendations: Air Compressors for Safety and Energy Saving’ (previous edition)”
- Meiji Kikai Seisakusho, "Air-cooled oil-free compressor operation manual (A(D)PF-22, FOK-22)"
- ANEST IWATA, "Daily inspection of reciprocating compressors (package type)" (CLP37EF-8.5(D) periodic inspection and maintenance reference table)
- Japan Society of Industrial Machinery Manufacturers (JSIM), General-Purpose Compressor Committee, pamphlet "Recommendations for Maintenance: Air Compressors for 'Safety and Energy Saving'" (February 2026 edition)
- Japan Industrial Machinery Manufacturers Association (JSIM), General-Purpose Compressor Committee, “Pamphlet ‘For Installing Air Compressors Safely’ (posted on the AIRMAN site)”
- ANEST IWATA, “Basics: ‘About Ventilation Volume’”
- ANEST IWATA, Notice, "Request to check the lubricating oil of oil-lubricated reciprocating compressors" (December 2020)
- ANEST IWATA, Basic knowledge, "Amount of water separated in the air tank"
- Ministry of Health, Labour and Welfare (MHLW), Safety Site for the Workplace, Industrial Accident Case “Air Tank Ruptured”
- Ministry of Health, Labour and Welfare (MHLW), "Ordinance on Safety of Boilers and Pressure Vessels" (e-Gov Law Search, Articles 84 and 86–89)
- Ministry of Health, Labour and Welfare (MHLW), Safety Site for the Workplace, Industrial Accident Case “Homemade Air Tank Ruptured”