G7 tolerance (hole) — limit deviations

Upper and lower limit deviations of hole tolerance class G7 (holes use capital letters), in µm (0.001 mm). Add them to the nominal size to get the permitted size range. Example: a Ø25 G7 hole must be between 25.007 and 25.028 mm.

G7 limit deviations (µm)

Nominal size (mm)UpperLowerToleranceCalc
up to 3+12+210→
over 3 to 6+16+412→
over 6 to 10+20+515→
over 10 to 14+24+618→
over 14 to 18+24+618→
over 18 to 24+28+721→
over 24 to 30+28+721→
over 30 to 40+34+925→
over 40 to 50+34+925→
over 50 to 65+40+1030→
over 65 to 80+40+1030→
over 80 to 100+47+1235→
over 100 to 120+47+1235→
over 120 to 140+54+1440→
over 140 to 160+54+1440→
over 160 to 180+54+1440→
over 180 to 200+61+1546→
over 200 to 225+61+1546→
over 225 to 250+61+1546→
over 250 to 280+69+1752→
over 280 to 315+69+1752→
over 315 to 355+75+1857→
over 355 to 400+75+1857→
over 400 to 450+83+2063→
over 450 to 500+83+2063→

Worked examples: permitted size limits for G7

1 µm = 0.001 mm. Add the upper and lower deviations to the nominal size D to obtain the maximum limit, minimum limit, and mean (target center) size.

Nominal DSize step (mm)Deviations (µm)Max. limit (mm)Min. limit (mm)Mean (target)Width (µm)
Ø10 G7over 6 to 10+20 / +510.02010.00510.0125 (+12.5 µm)15
Ø25 G7over 24 to 30+28 / +725.02825.00725.0175 (+17.5 µm)21
Ø50 G7over 40 to 50+34 / +950.03450.00950.0215 (+21.5 µm)25
Ø100 G7over 65 to 80+40 / +10100.040100.010100.025 (+25 µm)30

Notice that ISO 286 size steps are “over a up to and including b”: for example, exactly Ø10 mm belongs to “over 6 to 10”, not “over 10 to 18”. For any diameter or mating tolerance, use the ISO fit calculator.

Understanding G7: symbol breakdown, machining and inspection

Common fits that use this class

Partners of G7 in the table of preferred fits in the 1998 edition of JIS B 0401, the Japanese counterpart of ISO 286. Click one to open it in the calculator.

The current edition, JIS B 0401-1:2016 (identical to ISO 286-1:2010), has no table under that name; fits are covered in clause 5, “ISO fit system” (5.2 general fits and others), according to the table of contents in JSA’s public preview. The fit table from the 2016 edition quoted by MISUMI pairs classes differently from the 1998 table, so check which edition a drawing follows. Terms also changed: “basic size” became “nominal size” and “tolerance zone class” became “tolerance class” (Annex JA lists old and new terms).

Frequently asked questions (G7)

How do I calculate the maximum, minimum, and target size for Ø25 G7?
Ø25 mm falls in the “over 24 to 30 mm” step, where G7 has upper deviation +28 µm and lower deviation +7 µm (tolerance width 21 µm). Dividing by 1000 and adding to 25 mm gives a maximum limit of 25.028 mm, a minimum limit of 25.007 mm, and a mean target size of 25.0175 mm (+17.5 µm).
Which side of a boundary size (such as Ø6, Ø10, Ø18, Ø30, Ø50 mm) does G7 use?
In ISO 286 / JIS B 0401, every step is “over a up to and including b”. A nominal size right on the boundary always uses the upper row (“up to and including that number”), never the “over that number” row below it.
What mating classes are commonly paired with G7?
In the JIS B 0401 preferred-fits table, G7 is paired with G7/h6 (clearance). Click any chip above to check the exact clearance or interference in the calculator.

Sources

We compared the technical documents below and use values that agree in at least two of them.

  1. MISUMI jp.misumi-ec.com
  2. NBK (Nabeya Bi-tech) fujiikougyou.sakura.ne.jpfujiikougyou.sakura.ne.jpfujiikougyou.sakura.ne.jp
  3. Mitsubishi Materials mitsubishicarbide.netmitsubishicarbide.net
  4. OSG osg.co.jp
  5. Tungaloy tungaloy.com
  6. NSK nsk.com
  7. Miki Pulley mikipulley.co.jpmikipulley.co.jp
  8. Tsubakimoto Chain tt-net.tsubakimoto.co.jp
  9. KHK (Kohara Gear) khkgears.co.jpkhkgears.co.jp

Other hole tolerance classes

E7E8F6F7F8G6H5H6H7H8H9H10H11JS6JS7K6K7M6M7N6N7P6P7R7S7