Measuring by comparison
Radius gaugeRadius gauge
Also called: radius gauge, R gauge

Standards, measuring range and accuracy
- Standard
- No dedicated JIS or ISO standard number is given (depends on the manufacturer's criteria)
- Measuring range
- By manufacturer
- Shinwa Measuring Radius Scale A-1 R0.5–7 mm
- Shinwa Measuring A (34-leaf set) R1.0–7.0 mm
- Shinwa Measuring B (32-leaf set) R7.5–15 mm
- Niigata Seiki RG-26S R0.5–13.0 mm (0.5 mm steps)
- By manufacturer
- Resolution / graduation
- Description No graduations. The steps you can read are set by the R spacing of the leaves (example, 34-leaf set: 0.25 mm steps for R1–3 mm, 0.5 mm steps for R3.5–7 mm)
- Accuracy (instrument error / maximum permissible error)
- By manufacturer
- Shinwa Measuring Radius Scale A-1 R gauge part ±0.1 mm, diameter gauge part ±0.05 mm, rule ±0.15 mm
- Shinwa Measuring A (R1–7) ±0.1 mm
- Niigata Seiki RG-26S, single leaves ±0.1 mm
- Niigata Seiki RG-34F R0.10–3.00 mm: ±0.03 mm; R3.25–23.00 mm: ±0.04 mm
- By manufacturer
Metric ⇄ Inch & ASME/ISO Quick Reference: 1 mm = 0.03937 in (25.4 mm = 1 in) · 0.01 mm ≈ 0.0004 in (“4 tenths”) · 0.001 mm (1 µm) ≈ 0.00004 in (“40 millionths”). Standard reference temperature is 20 °C (68 °F) per ISO 1 / ASME B89.6.2. Related US standards: ASME B89.1.14 (calipers), ASME B89.1.13 (micrometers), ASME B89.1.10M (dial indicators), ASME B89.1.9 (gage blocks), ASME B89.3.7 (granite surface plates), ASME B1.2 (UN thread gages).
Types
Set of concave and convex leaves bundled together
Leaves for convex R and for concave R sit on the left and right. A 34-leaf set for R1–7 mm (0.25 mm steps up to R3 mm, 0.5 mm steps above that) is the most common; a 32-leaf set for R7.5–15 mm also exists[1][2][3]
Individual leaves (single or in a set)
Each size is separate, so it is easy to slip into hard-to-reach spots. A 26-leaf set covers R0.5–13 mm in 0.5 mm steps[4][5]One source / reference
Part names and functions
| # | Name | Function |
|---|---|---|
| 1 | Concave leaves, convex leaves | Use a concave leaf on the convex rounding of a workpiece (corner R) and a convex leaf on a concave rounding (inside corner or groove R)[2][1] |
| 2 | Screw and case | Bundle and hold the leaves. Remove the screw to take the leaves off[2] |
| 3 | Diameter gauge section (R scale) | Slide a round bar or plate into the gradually narrowing gap, and read the diameter or plate thickness from the scale where it stops[7] |
How to read the scale
- The R marked on the leaf that fits with no gap is the R of the workpiece[2][1]
- If no leaf fits exactly, read it as lying between two adjacent leavesExample: if neither R2.25 nor R2.5 fits exactly and the gaps show up in opposite ways, the R is between R2.25 and R2.5 (calculated from the rules in the source)[2]
- With the diameter gauge on the R scale, read the scale where the workpiece stops. Plate thickness can be read only when the cross section is square[7]
Usage steps
- Clean the leaves and the R portion of the workpieceClean the leaves well and apply rust-preventive oil before use[2]
- Use a concave leaf on workpiece corners (convex R) and a convex leaf on grooves and inside corners (concave R)[2][1]
- Face it toward a light and look for the R where no light leaks through the gapNot confirmed in public sources
- Also try the leaves one size above and below the one that seems to fitR steps are 0.25–0.5 mm, so an R in between does not fit any leaf exactly[1][2]
- When measuring diameter or plate thickness with the R scale, put it in the gap and slide it toward the narrow endRead the value where it stops. For plate thickness, put the plate against the scale side (valid only when the cross section is square)[7]
Printed from Kezuriba (kezuriba.net/en/gauges/radius-gauge/)
Common measurement mistakes and countermeasures
Judging a tolerance finer than the gauge's accuracy with a radius gauge
WhyMost radius gauges are ±0.1 mm accurate. They cannot decide pass or fail for a ±0.05 mm tolerance
CountermeasureChoose a gauge whose accuracy is well within the tolerance (some products are ±0.03 mm for R3 mm and under)[2][4][1]
Deciding from just the one leaf that fits
WhyAn R between the leaf steps does not fit any leaf perfectly
CountermeasureTry the leaves on either side too, and read the R as a range between the two leaves it lies between[1][2]
Measuring a plate whose cross section is not square with the R scale
WhyThe instruction manual says plate thickness measurement is valid only when the cross section is square
CountermeasureFor slanted or rounded edges, measure with another instrument such as a caliper[7]
Care, storage, inspection and calibration
Care and storage
- Do not drop it or subject it to strong impact (Shinwa manual)[6]
- Clean the leaves well and store them with rust-preventive oil[2]
- Leaf material differs by product (cold-rolled steel: Shinwa Measuring A and Niigata Seiki RG-34F; stainless steel: Niigata Seiki RG-26S). Watch for rust on steel leaves[2][1][4]
Inspection and calibration
Related instruments
Frequently asked questions about Radius gauge
- What should I check first before measuring with Radius gauge?
- Clean the leaves and the R portion of the workpiece Clean the leaves well and apply rust-preventive oil before use Always wipe dust, burrs, and cutting oil from both the measuring faces and the workpiece before taking a reading.
- What is the most common mistake when using Radius gauge, and how do I prevent it?
- Common error: Judging a tolerance finer than the gauge's accuracy with a radius gauge. Most radius gauges are ±0.1 mm accurate. They cannot decide pass or fail for a ±0.05 mm tolerance Countermeasure: Choose a gauge whose accuracy is well within the tolerance (some products are ±0.03 mm for R3 mm and under)
- How should Radius gauge be cared for, stored, and inspected?
- Care and storage: Do not drop it or subject it to strong impact (Shinwa manual) Inspection and calibration: Accuracy is set per product (±0.1 mm, ±0.03–0.04 mm, etc.). Before using it for judging, check that it is accurate enough for the tolerance you need
Sources
Content without a mark was confirmed by two or more sources from different publishers. Procedures and cautions are summarized in Kezuriba's own words based on the sources, and the figures were drawn by Kezuriba. Accuracy values are manufacturers' published figures unless noted otherwise (values taken from JIS tables are marked as such).
- Niigata Seiki, "Radius Gauge RG-34F (Product Information)"
- Shinwa Measuring, "Radius Gauge A R1–7 34-Leaf Set (Part No. 73767) Instruction Manual"
- Shinwa Measuring, "Radius Gauge B R7.5–15 32-Leaf Set (Part No. 73768) Instruction Manual"
- Niigata Seiki, "Radius Gauge Set RG-26S (Product Information)"
- Niigata Seiki, "Radius Gauge Leaf (Product Information)"
- Shinwa Measuring, "Radius Scale A-1 (44602/73570) Instruction Manual (English)"
- Shinwa Measuring, "Radius Scale A-1 R0.5–7 (Part No. 73570) Instruction Manual"