Threads and gears
Pitch gauge (thread pitch gauge)Screw pitch gauge
Also called: thread gauge (pitch), screw pitch gauge

Standards, measuring range and accuracy
- Standard
- No dedicated JIS or ISO standard number is given (depends on the manufacturer's criteria)
- Measuring range
- By manufacturer
- Niigata Seiki M28, Shinwa Measuring B-2 (metric) Pitch 0.25–2.5 mm (28 leaves)
- Niigata Seiki W26, Shinwa Measuring A-2 (inch) 4–60 threads per inch (26 leaves)
- By manufacturer
- Resolution / graduation
- Description No graduations. What you can tell apart is the pitch step of the leaves (example, 28-leaf metric set: 0.05 mm steps from 0.25–1.0 mm, 0.1 mm steps from 1.0–2.0 mm, plus 1.25, 1.75 and 2.5 mm)
Metric ⇄ Inch & ASME/ISO Quick Reference: 1 mm = 0.03937 in (25.4 mm = 1 in) · 0.01 mm ≈ 0.0004 in (“4 tenths”) · 0.001 mm (1 µm) ≈ 0.00004 in (“40 millionths”). Standard reference temperature is 20 °C (68 °F) per ISO 1 / ASME B89.6.2. Related US standards: ASME B89.1.14 (calipers), ASME B89.1.13 (micrometers), ASME B89.1.10M (dial indicators), ASME B89.1.9 (gage blocks), ASME B89.3.7 (granite surface plates), ASME B1.2 (UN thread gages).
Types
Part names and functions
How to read the scale
- Read the pitch marked on the leaf that meshes. Metric sets give mm; inch sets give threads per inchExample: if the "1.0" leaf meshes, the thread has a 1.0 mm distance between crests[2][4][1]
- Pitch alone does not determine the designation. Measure the outer diameter with a caliper and look up the designation in the thread table together with the pitchExample: an outer diameter of about 10 mm with 1.5 mm pitch is M10 coarse. With the same diameter and a finer pitch, it is a fine thread[5]
Usage steps
- Clean the leaf and the threadChips or oil left in the thread make the mesh hard to see. Clean the leaf well and apply rust-preventive oil before use[2][4]
- Hold the leaf against the thread parallel to the thread axis and find the leaf whose crests and roots mesh with no gap. Do not mix up the inch (threads per inch) and metric (pitch) leaves
- Try the leaf you guess, and if it does not fit, switch to the leaf with the next pitch up or downJust laying it along the external thread lets you check the pitch[1][2]
- If you cannot decide between close pitches, check over a long spanBoth the 1.75 mm and 1.8 mm leaves are in the set. The difference is 0.05 mm per thread, but over 10 threads it adds up to 0.5 mm, so held against a long run the threads look shifted at the end (calculated example)[2]
- Judge pass or fail with thread limit gaugesA pitch gauge is a tool for telling pitches apart. To judge whether the thread (pitch diameter) is acceptable, use limit gauges[6]
Printed from Kezuriba (kezuriba.net/en/gauges/screw-pitch-gauge/)
Common measurement mistakes and countermeasures
Mixing up metric and inch leaves
WhyWhen the pitches are close, leaves from the other series can seem to mesh for a few threads. The pitch of 25 threads per inch is 25.4 ÷ 25 = 1.016 mm, only 0.016 mm per thread from 1.0 mm (calculated example). Some inch leaves are 55° (for Whitworth threads)
CountermeasureKeep metric (60°) and inch leaves separate, and check the marking (mm or thread count) before holding one up[2][4][3]
Deciding after checking only a few threads
WhyEven a leaf with a close pitch can look like a fit over a few threads
CountermeasureLay it along the full length of the thread and see whether the threads line up to the end[2]
Deciding whether a thread passes with a pitch gauge
WhyEven when the pitch matches, the pitch diameter is not necessarily within tolerance
CountermeasureJudge pass or fail with thread limit gauges[6]
Care, storage, inspection and calibration
Care and storage
- Clean the leaves well and store them with rust-preventive oil (leaf material is carbon tool steel or carbon steel for machine structural use)[2][1]
- Remove the screw to take the leaves off. Do not use a bent leaf as it is[2]
Inspection and calibration
- A pitch gauge is for identification, and no accuracy value is given (Shinwa Measuring and Niigata Seiki specifications). For threads that need guaranteed dimensions, check with limit gauges[2][1][6]
It is for identifying pitch; use limit gauges for pass/fail judgment of threads (OSG's material says thread limit gauges check the overall pitch diameter).
Related instruments
Frequently asked questions about Screw pitch gauge
- What should I check first before measuring with Screw pitch gauge?
- Clean the leaf and the thread Chips or oil left in the thread make the mesh hard to see. Clean the leaf well and apply rust-preventive oil before use Always wipe dust, burrs, and cutting oil from both the measuring faces and the workpiece before taking a reading.
- What is the most common mistake when using Screw pitch gauge, and how do I prevent it?
- Common error: Mixing up metric and inch leaves. When the pitches are close, leaves from the other series can seem to mesh for a few threads. The pitch of 25 threads per inch is 25.4 ÷ 25 = 1.016 mm, only 0.016 mm per thread from 1.0 mm (calculated example). Some inch leaves are 55° (for Whitworth threads) Countermeasure: Keep metric (60°) and inch leaves separate, and check the marking (mm or thread count) before holding one up
- How should Screw pitch gauge be cared for, stored, and inspected?
- Care and storage: Clean the leaves well and store them with rust-preventive oil (leaf material is carbon tool steel or carbon steel for machine structural use) Inspection and calibration: A pitch gauge is for identification, and no accuracy value is given (Shinwa Measuring and Niigata Seiki specifications). For threads that need guaranteed dimensions, check with limit gauges
Sources
Content without a mark was confirmed by two or more sources from different publishers. Procedures and cautions are summarized in Kezuriba's own words based on the sources, and the figures were drawn by Kezuriba. Accuracy values are manufacturers' published figures unless noted otherwise (values taken from JIS tables are marked as such).
- Niigata Seiki, "Pitch Gauge M28 (Product Information)"
- Shinwa Measuring, "Pitch Gauge B-2 Metric 28 Leaves (Part No. 73795) Instruction Manual"
- Niigata Seiki, "Pitch Gauge W26 (Product Information)"
- Shinwa Measuring, "Pitch Gauge A-2 Inch 26 Leaves (Part No. 73794) Instruction Manual"
- Iwata Manufacturing, "Technical Data (Basic Dimensions of Metric Coarse Threads)"
- OSG, "Technical Data Series No. 2: Thread Gauges (revised May 2016)"