Measuring length
Depth micrometerDepth micrometer
Also called: interchangeable-rod depth micrometer

Standards, measuring range and accuracy
- Standard
- JIS B 7544:1994 Depth micrometers, ASME B89.1.13 Micrometers (including depth)[1][2]
- Measuring range
- By manufacturer
- Mitutoyo DMC (129-109 and others) 0–50 / 75 / 100 / 150 mm (interchangeable rods)
- By manufacturer
- Resolution / graduation
- By manufacturer
- Mitutoyo DMC Resolution 0.01 mm
- By manufacturer
- Accuracy (instrument error / maximum permissible error)
- By manufacturer
- Mitutoyo DMC60 (base width 60) Flatness of reference face 1.3 µm, flatness of measuring face 0.3 µm
- By manufacturer
Metric ⇄ Inch & ASME/ISO Quick Reference: 1 mm = 0.03937 in (25.4 mm = 1 in) · 0.01 mm ≈ 0.0004 in (“4 tenths”) · 0.001 mm (1 µm) ≈ 0.00004 in (“40 millionths”). Standard reference temperature is 20 °C (68 °F) per ISO 1 / ASME B89.6.2. Related US standards: ASME B89.1.14 (calipers), ASME B89.1.13 (micrometers), ASME B89.1.10M (dial indicators), ASME B89.1.9 (gage blocks), ASME B89.3.7 (granite surface plates), ASME B1.2 (UN thread gages).
Types
Part names and functions
| # | Name | Function |
|---|---|---|
| 1 | Base (reference surface) | Pressed against the top surface of the workpiece. Large area.[3][4] |
| 2 | Rod (measuring face) | Swapped onto the tip of the spindle to change the range.[3][4] |
| 3 | Thimble, sleeve, ratchet stop | The part that advances the spindle and reads the scale, and the constant-force device that equalizes the measuring force (same as on an outside micrometer)[3][4] |
| 4 | Rod collar | When changing rods, remove dirt from the contact area with the spindle end face.[4] |
How to read the scale
Usage steps
- Turn the thimble through its full travel to check operation, and remove dirt from the reference face and measuring face[4]
- Press the reference face against a surface with guaranteed flatness such as a precision surface plate, turn the ratchet stop 3–5 turns, and confirm the zero point. If the zero point is 25 mm or more, use gauge blocks[4]
- If the zero point is off, turn the sleeve (barrel) to adjust it[4]
- When measuring hole depth the bottom is often not visible, so move the base and measure several times to confirm that the rod is touching the bottom[3]
- Read from the front, and for long sessions check the zero point periodically[4]
Printed from Kezuriba (kezuriba.net/en/gauges/depth-micrometer/)
Common measurement mistakes and countermeasures
Dirt, oil, and burrs on the reference surface
WhyThe base area is large, so it is easily affected
CountermeasureClean the reference surface of the workpiece and remove burrs[3]
Care, storage, inspection and calibration
Care and storage
- After use, check for damage and clean, and store with the clamp released. For long-term storage, apply rust prevention to the rods and reference face and remove the battery[4]
Inspection and calibration
- Check the zero point with a precision surface plate and gauge blocks[4]
Related instruments
Frequently asked questions about Depth micrometer
- What should I check first before measuring with Depth micrometer?
- Turn the thimble through its full travel to check operation, and remove dirt from the reference face and measuring face Always wipe dust, burrs, and cutting oil from both the measuring faces and the workpiece before taking a reading.
- What is the most common mistake when using Depth micrometer, and how do I prevent it?
- Common error: Dirt, oil, and burrs on the reference surface. The base area is large, so it is easily affected Countermeasure: Clean the reference surface of the workpiece and remove burrs
- How should Depth micrometer be cared for, stored, and inspected?
- Care and storage: After use, check for damage and clean, and store with the clamp released. For long-term storage, apply rust prevention to the rods and reference face and remove the battery Inspection and calibration: Check the zero point with a precision surface plate and gauge blocks
Sources
Content without a mark was confirmed by two or more sources from different publishers. Procedures and cautions are summarized in Kezuriba's own words based on the sources, and the figures were drawn by Kezuriba. Accuracy values are manufacturers' published figures unless noted otherwise (values taken from JIS tables are marked as such).
- Japanese Standards Association (JSA), "JIS B 7544:1994 Depth micrometers (bibliographic record)"
- ASME, "ASME B89.1.13 Micrometers"
- Niigata University, "Niigata University Faculty of Engineering, Technical Staff Training Text, Chapter 1: Workshop Measurement"
- Mitutoyo, "How to Use Interchangeable-Rod Depth Micrometers"
- Mitutoyo, "Depth Micrometer DMC 129-109 Specifications"