Angles and flatness

V-blockV-block (Vee block)

Also called: Vee block

Illustration of using a V-block

Standards, measuring range and accuracy

Standard
JIS B 7540:1972 V-blocks[1]One source / reference
Measuring range
  • By manufacturer
    • Obishi Keiki hardened steel precision V-block Nominal 38 (applicable diameter 4–25 mm) to 250 (7–205 mm)
[2]One source / reference
Accuracy (instrument error / maximum permissible error)
  • By manufacturer
    • Obishi Keiki JA101/JA201 (nominal 38) Parallelism of base to V-groove: grade AA 3 µm, grade A 5 µm
[2]One source / reference

Metric ⇄ Inch & ASME/ISO Quick Reference: 1 mm = 0.03937 in (25.4 mm = 1 in) · 0.01 mm ≈ 0.0004 in (“4 tenths”) · 0.001 mm (1 µm) ≈ 0.00004 in (“40 millionths”). Standard reference temperature is 20 °C (68 °F) per ISO 1 / ASME B89.6.2. Related US standards: ASME B89.1.14 (calipers), ASME B89.1.13 (micrometers), ASME B89.1.10M (dial indicators), ASME B89.1.9 (gage blocks), ASME B89.3.7 (granite surface plates), ASME B1.2 (UN thread gages).

Types

Precision hardened steel (pair of 2, hardened, 90° V-groove), carbide-tipped, with clamp, cast iron (type A, type B, with fittings), stone, box-type block with V-groove

[2][3]One source / reference

Part names and functions

#NameFunction
1V-groove / base / side facesSold as a pair of 2, with the parallelism of base and V-groove matched.[2]

Usage steps

  1. Used for inspecting round workpieces and as an auxiliary block (shojikidai)[2]
  2. Before use, clean the working surface and the workpiece and let them settle to the same temperature. Remove light scratches locally with an Arkansas stone, etc.[2]
  3. Place the V-block on a reference surface plate, rest the round workpiece in the V-groove, and touch the dial indicator contact point to the workpiece to measure parallelism or eccentricity. Slide the indicator stand across the surface plate to move it.[2]
  4. Set top face up on the surface plate, it also serves as a parallel block. Touch the dial indicator to the workpiece placed on it to measure parallelism and straightness.[2]

Common measurement mistakes and countermeasures

Dropping or impact

WhyIf dropped, the V-groove faces can get dents and burrs, throwing off the groove angle and parallelism with the base

CountermeasureCheck for abnormalities before use[2]

Care, storage, inspection and calibration

Care and storage

Inspection and calibration

Related instruments

Frequently asked questions about V-block (Vee block)

What should I check first before measuring with V-block (Vee block)?
Used for inspecting round workpieces and as an auxiliary block (shojikidai) Always wipe dust, burrs, and cutting oil from both the measuring faces and the workpiece before taking a reading.
What is the most common mistake when using V-block (Vee block), and how do I prevent it?
Common error: Dropping or impact. If dropped, the V-groove faces can get dents and burrs, throwing off the groove angle and parallelism with the base Countermeasure: Check for abnormalities before use
How should V-block (Vee block) be cared for, stored, and inspected?
Care and storage: After use, rust-proof and store in a storage box Inspection and calibration: Check accuracy periodically

Sources

Content without a mark was confirmed by two or more sources from different publishers. Procedures and cautions are summarized in Kezuriba's own words based on the sources, and the figures were drawn by Kezuriba. Accuracy values are manufacturers' published figures unless noted otherwise (values taken from JIS tables are marked as such).

  1. Japanese Standards Association (JSA), "JIS B 7540:1972 V-blocks (bibliographic record)"
  2. Obishi Keiki, "Hardened Steel Precision V-Block Instruction Manual JA201"
  3. Obishi Keiki, "Cast Iron Type-A V-Block Instruction Manual JE201"