Angles and flatness
Precision squareSquare (engineer's square)
Also called: engineer's square, I-type square, square with base

Standards, measuring range and accuracy
- Standard
- JIS B 7526:1995 Squares[1][2]
- Measuring range
- By manufacturer
- Obishi Keiki I-type Nominal 50–1000 mm
- Obishi Keiki flat square Nominal 75–600 mm and up
- Obishi Keiki precision cylindrical square Nominal 100–600 mm and up
- By manufacturer
- Resolution / graduation
- Description No graduations. Deviation from square is seen from light passing through the gap, or with a feeler gauge
- Accuracy (instrument error / maximum permissible error)
- By manufacturer
- Obishi Keiki I-type, nominal 100 Squareness grade 1 ±3.0 µm, grade 2 ±7.0 µm
- Obishi Keiki knife-edge square (Type III), nominal 100 Squareness ±3.0 µm
- Obishi Keiki flat square with base, grade 1, nominal 100 Squareness ±15 µm
- Obishi Keiki precision cylindrical square, nominal 100 Squareness 2.5 µm
- By manufacturer
Metric ⇄ Inch & ASME/ISO Quick Reference: 1 mm = 0.03937 in (25.4 mm = 1 in) · 0.01 mm ≈ 0.0004 in (“4 tenths”) · 0.001 mm (1 µm) ≈ 0.00004 in (“40 millionths”). Standard reference temperature is 20 °C (68 °F) per ISO 1 / ASME B89.6.2. Related US standards: ASME B89.1.14 (calipers), ASME B89.1.13 (micrometers), ASME B89.1.10M (dial indicators), ASME B89.1.9 (gage blocks), ASME B89.3.7 (granite surface plates), ASME B1.2 (UN thread gages).
Types
Flat square
A plate-type square. Nominal 75–600 mm and up. Grade 1, nominal 100 mm: squareness ±15 µm (Obishi Keiki)[3]One source / reference
Square with base
The short blade (base) is thick, so it sits stable against a workpiece or surface plate. Center, right-hand and left-hand types exist. Grade 1, nominal 100 mm: ±15 µm (Obishi Keiki)[4]One source / reference
I-shaped square
It is thick and stands stable on end. Accurate enough to serve as a master for measuring instruments. At nominal 100 mm: grade 1 ±3.0 µm, grade 2 ±7.0 µm (Obishi Keiki)[2][5]One source / reference
Knife-edge square
The inner and outer corners of the long blade are knife-edged (a very small R), so light passes easily and it is easy to use. At nominal 100 mm: ±3.0 µm (Obishi Keiki)[6]One source / reference
Cylindrical square (JIS B 7539)
It touches the workpiece along a single line of the cylinder, so it measures extremely accurately. Used as a master for squareness measurement. At nominal 100 mm: squareness 2.5 µm (Obishi Keiki)[7]One source / reference
Part names and functions
| # | Name | Function |
|---|---|---|
| 1 | Long blade | The long edge laid along the workpiece (nominal size H). Both inner and outer corners can be used for measuring[2][6] |
| 2 | Short blade (base) | The short edge placed on the surface plate or the workpiece's reference surface. On a base type the short blade is thick and rigidly joined to the long blade[4] |
| 3 | Working face | The face placed against the workpiece. Clean it before use[2] |
Usage steps
- Let it come to the temperature of the place where it is used, and clean the working face and the workpiece's measuring surface[2]
- Stand the square on the surface plate and put the working face against the workpieceCheck the gap between the square and the workpiece by how light passes through, or with a feeler gauge (Fig. 2.A in Obishi Keiki's manual)[2]
- Put the side face of the square against the side of the workpiece and check squarenessIt can also serve as a reference when setting up parts (Fig. 2.B)[2]
- For checking with light, a knife-edge square is easier to seeThe inner and outer corners of the long blade are knife-edged, so light passes easily[6]
- To know the deviation as a number, use a squareness testerA device that takes a dial indicator (sold separately) to read the straightness or squareness of the measuring surface[8]
Printed from Kezuriba (kezuriba.net/en/gauges/square/)
Common measurement mistakes and countermeasures
Measuring without letting it come to temperature, or using it where the temperature changes a lot
WhyBoth the square and the workpiece expand and contract with temperature. The manual says to let it come to the temperature of the place of use and not to use it where the temperature changes sharply
CountermeasureLet them sit for a while before use so they reach the same temperature[2]
Putting it on without wiping dirt off the working face or workpiece
WhyTrapped dust lifts it by that amount, and the gap looks like a deviation from square
CountermeasureClean the working face and the workpiece's measuring surface before use[2]
Using a square that was dropped as it is
WhyIf it has been dropped, or something has been dropped on it, it may be out of square
CountermeasureCheck that nothing is wrong before use. If it is damaged, send it for repair or inspection[2]
Care, storage, inspection and calibration
Care and storage
- After use, apply rust prevention and store it in a storage case[2]
- Handle it so as not to subject it to shock, both in use and in storage[2]
- Do not use or store it where the temperature changes sharply[2]
- Light scratches on the working face can be removed locally with an Arkansas stone or similar before use[2]
Inspection and calibration
- Check accuracy (squareness) periodically[2]
- Cylindrical squares are used as the master for squareness. Obishi Keiki calls the cylindrical square a "master for squareness measurement"[7]
- Some measuring instrument makers that make squares offer calibration services (Obishi Keiki)[2]
Uses: checking the squareness of jigs and fixtures, checking squareness after mounting them, and measuring the squareness of products. High-accuracy ones also serve as masters for measuring instruments (Obishi Keiki).
Related instruments
Frequently asked questions about Square (engineer's square)
- What should I check first before measuring with Square (engineer's square)?
- Let it come to the temperature of the place where it is used, and clean the working face and the workpiece's measuring surface Always wipe dust, burrs, and cutting oil from both the measuring faces and the workpiece before taking a reading.
- What is the most common mistake when using Square (engineer's square), and how do I prevent it?
- Common error: Measuring without letting it come to temperature, or using it where the temperature changes a lot. Both the square and the workpiece expand and contract with temperature. The manual says to let it come to the temperature of the place of use and not to use it where the temperature changes sharply Countermeasure: Let them sit for a while before use so they reach the same temperature
- How should Square (engineer's square) be cared for, stored, and inspected?
- Care and storage: After use, apply rust prevention and store it in a storage case Inspection and calibration: Check accuracy (squareness) periodically
Sources
Content without a mark was confirmed by two or more sources from different publishers. Procedures and cautions are summarized in Kezuriba's own words based on the sources, and the figures were drawn by Kezuriba. Accuracy values are manufacturers' published figures unless noted otherwise (values taken from JIS tables are marked as such).
- Japanese Standards Association (JSA), "JIS B 7526:1995 Squares (bibliographic record)"
- Obishi Keiki, "I-Type Square Instruction Manual FG202"
- Obishi Keiki, "Flat Square (Product Catalog)"
- Obishi Keiki, "Square with Base (Product Catalog)"
- Obishi Keiki, "I-Type Square (Product Catalog)"
- Obishi Keiki, "Knife-Edge Square (Type III) (Product Catalog)"
- Obishi Keiki, "Precision Cylindrical Square (Product Catalog)"
- Obishi Keiki, "Squareness Tester (Product Catalog)"