f6 tolerance (shaft) — limit deviations
Upper and lower limit deviations of shaft tolerance class f6 (shafts use lower-case letters), in µm (0.001 mm). Add them to the nominal size to get the permitted size range. Example: a Ø25 f6 shaft must be between 24.967 and 24.980 mm.
f6 limit deviations (µm)
| Nominal size (mm) | Upper | Lower | Tolerance | Calc |
|---|---|---|---|---|
| up to 3 | −6 | −12 | 6 | → |
| over 3 to 6 | −10 | −18 | 8 | → |
| over 6 to 10 | −13 | −22 | 9 | → |
| over 10 to 14 | −16 | −27 | 11 | → |
| over 14 to 18 | −16 | −27 | 11 | → |
| over 18 to 24 | −20 | −33 | 13 | → |
| over 24 to 30 | −20 | −33 | 13 | → |
| over 30 to 40 | −25 | −41 | 16 | → |
| over 40 to 50 | −25 | −41 | 16 | → |
| over 50 to 65 | −30 | −49 | 19 | → |
| over 65 to 80 | −30 | −49 | 19 | → |
| over 80 to 100 | −36 | −58 | 22 | → |
| over 100 to 120 | −36 | −58 | 22 | → |
| over 120 to 140 | −43 | −68 | 25 | → |
| over 140 to 160 | −43 | −68 | 25 | → |
| over 160 to 180 | −43 | −68 | 25 | → |
| over 180 to 200 | −50 | −79 | 29 | → |
| over 200 to 225 | −50 | −79 | 29 | → |
| over 225 to 250 | −50 | −79 | 29 | → |
| over 250 to 280 | −56 | −88 | 32 | → |
| over 280 to 315 | −56 | −88 | 32 | → |
| over 315 to 355 | −62 | −98 | 36 | → |
| over 355 to 400 | −62 | −98 | 36 | → |
| over 400 to 450 | −68 | −108 | 40 | → |
| over 450 to 500 | −68 | −108 | 40 | → |
Worked examples: permitted size limits for f6
1 µm = 0.001 mm. Add the upper and lower deviations to the nominal size D to obtain the maximum limit, minimum limit, and mean (target center) size.
| Nominal D | Size step (mm) | Deviations (µm) | Max. limit (mm) | Min. limit (mm) | Mean (target) | Width (µm) |
|---|---|---|---|---|---|---|
| Ø10 f6 | over 6 to 10 | −13 / −22 | 9.987 | 9.978 | 9.9825 (−17.5 µm) | 9 |
| Ø25 f6 | over 24 to 30 | −20 / −33 | 24.980 | 24.967 | 24.9735 (−26.5 µm) | 13 |
| Ø50 f6 | over 40 to 50 | −25 / −41 | 49.975 | 49.959 | 49.967 (−33 µm) | 16 |
| Ø100 f6 | over 65 to 80 | −30 / −49 | 99.970 | 99.951 | 99.9605 (−39.5 µm) | 19 |
Notice that ISO 286 size steps are “over a up to and including b”: for example, exactly Ø10 mm belongs to “over 6 to 10”, not “over 10 to 18”. For any diameter or mating tolerance, use the ISO fit calculator.
Understanding f6: symbol breakdown, machining and inspection
- Fundamental deviation letter “f” (shaft): Shaft tolerance zone with a negative (−) upper deviation es. The shaft is always smaller than the nominal size, giving a clearance fit with an H hole.
- Tolerance grade “IT6”: IT6 is a high-precision grade typically finished by cylindrical/internal grinding, fine boring, precision turning, or carbide reaming, and inspected with micrometers, bore gauges, or limit gauges.
- Thermal expansion & measuring instruments: Dimensional tolerances in ISO / JIS are defined at 20 °C. Check thermal growth right after cutting with the thermal expansion calculator, compare micrometers, bore gauges, and plug/pin gauges in the measuring instruments guide, and review Abbe’s principle and measurement uncertainty in Measurement errors explained.
Common fits that use this class
Partners of f6 in the table of preferred fits in the 1998 edition of JIS B 0401, the Japanese counterpart of ISO 286. Click one to open it in the calculator.
The current edition, JIS B 0401-1:2016 (identical to ISO 286-1:2010), has no table under that name; fits are covered in clause 5, “ISO fit system” (5.2 general fits and others), according to the table of contents in JSA’s public preview. The fit table from the 2016 edition quoted by MISUMI pairs classes differently from the 1998 table, so check which edition a drawing follows. Terms also changed: “basic size” became “nominal size” and “tolerance zone class” became “tolerance class” (Annex JA lists old and new terms).
Frequently asked questions (f6)
- How do I calculate the maximum, minimum, and target size for Ø25 f6?
- Ø25 mm falls in the “over 24 to 30 mm” step, where f6 has upper deviation −20 µm and lower deviation −33 µm (tolerance width 13 µm). Dividing by 1000 and adding to 25 mm gives a maximum limit of 24.980 mm, a minimum limit of 24.967 mm, and a mean target size of 24.9735 mm (−26.5 µm).
- Which side of a boundary size (such as Ø6, Ø10, Ø18, Ø30, Ø50 mm) does f6 use?
- In ISO 286 / JIS B 0401, every step is “over a up to and including b”. A nominal size right on the boundary always uses the upper row (“up to and including that number”), never the “over that number” row below it.
- What mating classes are commonly paired with f6?
- In the JIS B 0401 preferred-fits table, f6 is paired with H6/f6 (clearance), H7/f6 (clearance). Click any chip above to check the exact clearance or interference in the calculator.
Sources
We compared the technical documents below and use values that agree in at least two of them.
- MISUMI jp.misumi-ec.com
- NBK (Nabeya Bi-tech) fujiikougyou.sakura.ne.jpfujiikougyou.sakura.ne.jpfujiikougyou.sakura.ne.jp
- Mitsubishi Materials mitsubishicarbide.netmitsubishicarbide.net
- OSG osg.co.jp
- Tungaloy tungaloy.com
- NSK nsk.com
- Miki Pulley mikipulley.co.jpmikipulley.co.jp
- KHK (Kohara Gear) khkgears.co.jpkhkgears.co.jp