s6 tolerance (shaft) — limit deviations
Upper and lower limit deviations of shaft tolerance class s6 (shafts use lower-case letters), in µm (0.001 mm). Add them to the nominal size to get the permitted size range. Example: a Ø25 s6 shaft must be between 25.035 and 25.048 mm.
s6 limit deviations (µm)
| Nominal size (mm) | Upper | Lower | Tolerance | Calc |
|---|---|---|---|---|
| up to 3 | +20 | +14 | 6 | → |
| over 3 to 6 | +27 | +19 | 8 | → |
| over 6 to 10 | +32 | +23 | 9 | → |
| over 10 to 14 | +39 | +28 | 11 | → |
| over 14 to 18 | +39 | +28 | 11 | → |
| over 18 to 24 | +48 | +35 | 13 | → |
| over 24 to 30 | +48 | +35 | 13 | → |
| over 30 to 40 | +59 | +43 | 16 | → |
| over 40 to 50 | +59 | +43 | 16 | → |
| over 50 to 65 | +72 | +53 | 19 | → |
| over 65 to 80 | +78 | +59 | 19 | → |
| over 80 to 100 | +93 | +71 | 22 | → |
| over 100 to 120 | +101 | +79 | 22 | → |
| over 120 to 140 | +117 | +92 | 25 | → |
| over 140 to 160 | +125 | +100 | 25 | → |
| over 160 to 180 | +133 | +108 | 25 | → |
| over 180 to 200 | +151 | +122 | 29 | → |
| over 200 to 225 | +159 | +130 | 29 | → |
| over 225 to 250 | +169 | +140 | 29 | → |
| over 250 to 280 | — | — | — | |
| over 280 to 315 | — | — | — | |
| over 315 to 355 | — | — | — | |
| over 355 to 400 | — | — | — | |
| over 400 to 450 | — | — | — | |
| over 450 to 500 | — | — | — |
Note: The JIS B 0401 table of preferred fits gives no values above 250 mm, and none of the technical charts we checked go beyond 250 mm.
“—” means no primary source with values was found for that size range (we do not fill gaps by calculation).
Worked examples: permitted size limits for s6
1 µm = 0.001 mm. Add the upper and lower deviations to the nominal size D to obtain the maximum limit, minimum limit, and mean (target center) size.
| Nominal D | Size step (mm) | Deviations (µm) | Max. limit (mm) | Min. limit (mm) | Mean (target) | Width (µm) |
|---|---|---|---|---|---|---|
| Ø10 s6 | over 6 to 10 | +32 / +23 | 10.032 | 10.023 | 10.0275 (+27.5 µm) | 9 |
| Ø25 s6 | over 24 to 30 | +48 / +35 | 25.048 | 25.035 | 25.0415 (+41.5 µm) | 13 |
| Ø50 s6 | over 40 to 50 | +59 / +43 | 50.059 | 50.043 | 50.051 (+51 µm) | 16 |
| Ø100 s6 | over 65 to 80 | +78 / +59 | 100.078 | 100.059 | 100.0685 (+68.5 µm) | 19 |
Notice that ISO 286 size steps are “over a up to and including b”: for example, exactly Ø10 mm belongs to “over 6 to 10”, not “over 10 to 18”. For any diameter or mating tolerance, use the ISO fit calculator or press-fit & shrink-fit calculator.
Understanding s6: symbol breakdown, machining and inspection
- Fundamental deviation letter “s” (shaft): Shaft tolerance zone with a positive (+) lower deviation ei. The shaft is larger than the nominal size, giving an interference (press or shrink) fit with an H hole.
- Tolerance grade “IT6”: IT6 is a high-precision grade typically finished by cylindrical/internal grinding, fine boring, precision turning, or carbide reaming, and inspected with micrometers, bore gauges, or limit gauges.
- Thermal expansion & measuring instruments: Dimensional tolerances in ISO / JIS are defined at 20 °C. Check thermal growth right after cutting with the thermal expansion calculator, compare micrometers, bore gauges, and plug/pin gauges in the measuring instruments guide, and review Abbe’s principle and measurement uncertainty in Measurement errors explained.
Common fits that use this class
Partners of s6 in the table of preferred fits in the 1998 edition of JIS B 0401, the Japanese counterpart of ISO 286. Click one to open it in the calculator.
The current edition, JIS B 0401-1:2016 (identical to ISO 286-1:2010), has no table under that name; fits are covered in clause 5, “ISO fit system” (5.2 general fits and others), according to the table of contents in JSA’s public preview. The fit table from the 2016 edition quoted by MISUMI pairs classes differently from the 1998 table, so check which edition a drawing follows. Terms also changed: “basic size” became “nominal size” and “tolerance zone class” became “tolerance class” (Annex JA lists old and new terms).
Frequently asked questions (s6)
- How do I calculate the maximum, minimum, and target size for Ø25 s6?
- Ø25 mm falls in the “over 24 to 30 mm” step, where s6 has upper deviation +48 µm and lower deviation +35 µm (tolerance width 13 µm). Dividing by 1000 and adding to 25 mm gives a maximum limit of 25.048 mm, a minimum limit of 25.035 mm, and a mean target size of 25.0415 mm (+41.5 µm).
- Which side of a boundary size (such as Ø6, Ø10, Ø18, Ø30, Ø50 mm) does s6 use?
- In ISO 286 / JIS B 0401, every step is “over a up to and including b”. A nominal size right on the boundary always uses the upper row (“up to and including that number”), never the “over that number” row below it.
- What mating classes are commonly paired with s6?
- In the JIS B 0401 preferred-fits table, s6 is paired with H7/s6 (interference). Click any chip above to check the exact clearance or interference in the calculator.
Sources
We compared the technical documents below and use values that agree in at least two of them.
- MISUMI jp.misumi-ec.com
- NBK (Nabeya Bi-tech) fujiikougyou.sakura.ne.jpfujiikougyou.sakura.ne.jpfujiikougyou.sakura.ne.jp
- Mitsubishi Materials mitsubishicarbide.netmitsubishicarbide.net
- KHK (Kohara Gear) khkgears.co.jpkhkgears.co.jp