r6 tolerance (shaft) — limit deviations

Upper and lower limit deviations of shaft tolerance class r6 (shafts use lower-case letters), in µm (0.001 mm). Add them to the nominal size to get the permitted size range. Example: a Ø25 r6 shaft must be between 25.028 and 25.041 mm.

▤r6 limit deviations (µm)

Nominal size (mm)UpperLowerToleranceCalc
up to 3+16+106→
over 3 to 6+23+158→
over 6 to 10+28+199→
over 10 to 14+34+2311→
over 14 to 18+34+2311→
over 18 to 24+41+2813→
over 24 to 30+41+2813→
over 30 to 40+50+3416→
over 40 to 50+50+3416→
over 50 to 65+60+4119→
over 65 to 80+62+4319→
over 80 to 100+73+5122→
over 100 to 120+76+5422→
over 120 to 140+88+6325→
over 140 to 160+90+6525→
over 160 to 180+93+6825→
over 180 to 200+106+7729→
over 200 to 225+109+8029→
over 225 to 250+113+8429→
over 250 to 280+126+9432→
over 280 to 315+130+9832→
over 315 to 355+144+10836→
over 355 to 400+150+11436→
over 400 to 450+166+12640→
over 450 to 500+172+13240→

⊂⊃Common fits that use this class

Partners of r6 in the preferred fits of JIS B 0401 (1998), the Japanese counterpart of ISO 286. Click one to open it in the calculator.

📚Sources

We compared the technical documents below and use values that agree in at least two of them.

  1. MISUMI jp.misumi-ec.com
  2. NBK (Nabeya Bi-tech) fujiikougyou.sakura.ne.jpfujiikougyou.sakura.ne.jpfujiikougyou.sakura.ne.jp
  3. Mitsubishi Materials mitsubishicarbide.netmitsubishicarbide.net
  4. NSK nsk.com
  5. Miki Pulley mikipulley.co.jpmikipulley.co.jp
  6. KHK (Kohara Gear) khkgears.co.jpkhkgears.co.jp

Other shaft tolerance classes

d9e7e8e9f6f7f8g5g6h5h6h7h8h9js5js6js7k5k6m5m6n6p6s6