Limit gauges and size gauges
Pin gaugePin gauge (plug gauge pin)
Also called: pin gauge set, steel pin gauges, carbide pin gauges

Standards, measuring range and accuracy
- Standard
- No dedicated JIS or ISO standard number is given (depends on the manufacturer's criteria)
- Measuring range
- By manufacturer
- Niigata Seiki PG series 0.100–0.290 mm (0.010 steps), 0.300–1.525 mm (0.025 steps), 1.550–6.275, 6.300–9.775, 9.800–12.525 mm (0.025 steps), etc.
- By manufacturer
- Resolution / graduation
- By manufacturer
- Niigata Seiki PG series Set size interval 0.010 mm or 0.025 mm
- By manufacturer
- Accuracy (instrument error / maximum permissible error)
- By manufacturer
- Niigata Seiki PG series (steel) Made 2–5 µm plus or minus of the nominal size. φ2.700 mm and up are sub-zero treated
- By manufacturer
Metric ⇄ Inch & ASME/ISO Quick Reference: 1 mm = 0.03937 in (25.4 mm = 1 in) · 0.01 mm ≈ 0.0004 in (“4 tenths”) · 0.001 mm (1 µm) ≈ 0.00004 in (“40 millionths”). Standard reference temperature is 20 °C (68 °F) per ISO 1 / ASME B89.6.2. Related US standards: ASME B89.1.14 (calipers), ASME B89.1.13 (micrometers), ASME B89.1.10M (dial indicators), ASME B89.1.9 (gage blocks), ASME B89.3.7 (granite surface plates), ASME B1.2 (UN thread gages).
Types
Part names and functions
| # | Name | Function |
|---|---|---|
| 1 | Pin body (from 1.000 mm up, marked with +/− and the dimension) | Passed through a hole to check its diameter.[1] |
How to read the scale
- Judge the hole-diameter range from the sizes of the pins that went in and the pins that did not
Usage steps
Printed from Kezuriba (kezuriba.net/en/gauges/pin-gauge/)
Common measurement mistakes and countermeasures
Holding by hand for a long time (thermal expansion) / forcing it in
WhyOSG's general cautions for limit gauges list dimensional change from hand heat, and accidents where a gauge forced through cannot be removed
CountermeasureUse gloves and a pin vise. Do not use force (not a statement specific to pin gauges)[3]
Care, storage, inspection and calibration
Care and storage
- Clean and rust-proof after use (as a general gauge caution)[3]
Inspection and calibration
Related instruments
Frequently asked questions about Pin gauge (plug gauge pin)
- What should I check first before measuring with Pin gauge (plug gauge pin)?
- Use: checking the accuracy of hole diameters, etc. Always wipe dust, burrs, and cutting oil from both the measuring faces and the workpiece before taking a reading.
- What is the most common mistake when using Pin gauge (plug gauge pin), and how do I prevent it?
- Common error: Holding by hand for a long time (thermal expansion) / forcing it in. OSG's general cautions for limit gauges list dimensional change from hand heat, and accidents where a gauge forced through cannot be removed Countermeasure: Use gloves and a pin vise. Do not use force (not a statement specific to pin gauges)
- How should Pin gauge (plug gauge pin) be cared for, stored, and inspected?
- Care and storage: Clean and rust-proof after use (as a general gauge caution) Inspection and calibration:
Sources
Content without a mark was confirmed by two or more sources from different publishers. Procedures and cautions are summarized in Kezuriba's own words based on the sources, and the figures were drawn by Kezuriba. Accuracy values are manufacturers' published figures unless noted otherwise (values taken from JIS tables are marked as such).