Limit gauge

Limit plain gauges (plug gauge, ring gauge, snap gauge)Plain limit gauge (plug / ring / snap gauge)

Also called: limit gauge, plug gauge, ring gauge, snap gauge, GO/NO-GO gauge

Illustration of using a plain limit gauge

≡Standards, measuring range and accuracy

Standard
JIS B 7420:1997 Limit plain gauges[1][2]
Measuring range
—Not confirmed in public sources
Resolution / graduation
  • Description No graduations; it only judges pass or fail
[2]1 source, for reference
Accuracy (instrument error / maximum permissible error)
—Not confirmed in public sourcesThe gauge tolerance tables have not been checked

▦Types

Plain plug gauge (for holes): GO end and NO-GO end

[2]1 source, for reference

Plain ring gauge (for shafts): GO end and NO-GO end

[2]1 source, for reference

Plain snap gauge (for shafts)

[2]1 source, for reference

Symbols: PP (plain plug), PR (plain ring), PC (plain caliper = snap gauge)

[2]1 source, for reference

◎Part names and functions

#NameEnglishFunction
1GO end and NO-GO endGo side / Not-go sideUsed as a pair.[2]

◷How to read the scale

  1. Pass if the GO end goes through and the NO-GO end stops[2]

✋Usage steps

  1. Wash the gauge and workpiece with cleaning oil, benzine, etc., or wipe them thoroughly with a clean cloth. Check the gauge for rust, scratches and burrs, and remove them with an oilstone if present[2]
  2. Apply lubricating oil to the gauge and brush chips and dust off the workpiece before inspecting (dust and grit speed up wear)[2]
  3. First check that the GO end goes through, then check that the NO-GO end stops[2]
  4. As a rule the force is the weight of the gauge itself (the working load for snap gauges). Hold small gauges lightly between the fingertips[2]
  5. Align the gauge and workpiece axes when fitting. If misaligned they may seize and become impossible to remove[2]

!Common measurement mistakes and countermeasures

Forcing it through or knocking it out

WhyScratches, cracks and deformation destroy the gauge's function

CountermeasureIf it seizes, tap lightly with a wooden or plastic hammer so the axes line up, or warm the ring side slightly to remove it[2]

Inspecting parts right after machining or parts held in the hand

WhyThermal expansion throws off the judgment. Thin-walled parts can cool and shrink onto the plug in a shrink-fit state

CountermeasureConsider the temperature difference between the gauge and the workpiece. Gauge dimensions are defined at 20 °C[2]

Dents and burrs at the mouth

WhyIt throws off the judgment

CountermeasureCheck the mouth of the part[2]

Inspecting a moving part

WhyDanger of dropping, breakage and flying parts

CountermeasureInspect while it is stopped[2]

✓Care, storage, inspection and calibration

Care and storage

Inspection and calibration

Taylor's principle (the GO gauge checks the overall form, while the NO-GO gauge checks one point at a time) appears by name only in OSG's material; no primary source defining it was found.

⇄Related instruments

📚Sources

Content without a mark is what agreed across two or more sources from different publishers. Procedures and cautions are summarized in Kezuriba's own words based on the sources, and the diagrams were drawn by Kezuriba. Accuracy values are manufacturers' published figures, not values from JIS tables.

  1. Japanese Standards Association (JSA), "JIS B 7420:1997 Limit plain gauges (bibliographic record)"
  2. OSG, "Technical Data Series No. 2: Thread Gauges (revised May 2016)"