Limit gauge

Limit plain gauges (plug gauge, ring gauge, snap gauge)Plain limit gauge (plug / ring / snap gauge)

Also called: limit gauge, plug gauge, ring gauge, snap gauge, GO/NO-GO gauge

Illustration of using a plain limit gauge

Standards, measuring range and accuracy

Standard
JIS B 7420:1997 Limit plain gauges[1][2]
Resolution / graduation
  • Description No graduations; it only judges pass or fail
[2]One source / reference

Metric ⇄ Inch & ASME/ISO Quick Reference: 1 mm = 0.03937 in (25.4 mm = 1 in) · 0.01 mm ≈ 0.0004 in (“4 tenths”) · 0.001 mm (1 µm) ≈ 0.00004 in (“40 millionths”). Standard reference temperature is 20 °C (68 °F) per ISO 1 / ASME B89.6.2. Related US standards: ASME B89.1.14 (calipers), ASME B89.1.13 (micrometers), ASME B89.1.10M (dial indicators), ASME B89.1.9 (gage blocks), ASME B89.3.7 (granite surface plates), ASME B1.2 (UN thread gages).

Types

Plain plug gauge (for holes): GO end and NO-GO end

[2]One source / reference

Plain ring gauge (for shafts): GO end and NO-GO end

[2]One source / reference

Plain snap gauge (for shafts)

[2]One source / reference

Symbols: PP (plain plug), PR (plain ring), PC (plain caliper = snap gauge)

[2]One source / reference

Part names and functions

#NameFunction
1GO end and NO-GO endUsed as a pair.[2]

How to read the scale

  1. Pass if the GO end goes through and the NO-GO end stops[2]

Usage steps

  1. Wash the gauge and workpiece with cleaning oil, benzine, etc., or wipe them thoroughly with a clean cloth. Check the gauge for rust, scratches and burrs, and remove them with an oilstone if present[2]
  2. Apply lubricating oil to the gauge and brush chips and dust off the workpiece before inspecting (dust and grit speed up wear)[2]
  3. First check that the GO end goes through, then check that the NO-GO end stops[2]
  4. As a rule the force is the weight of the gauge itself (the working load for snap gauges). Hold small gauges lightly between the fingertips[2]
  5. Align the gauge and workpiece axes when fitting. If misaligned they may seize and become impossible to remove[2]

Common measurement mistakes and countermeasures

Forcing it through or knocking it out

WhyScratches, cracks and deformation destroy the gauge's function

CountermeasureIf it seizes, tap lightly with a wooden or plastic hammer so the axes line up, or warm the ring side slightly to remove it[2]

Inspecting parts right after machining or parts held in the hand

WhyThermal expansion throws off the judgment. Thin-walled parts can cool and shrink onto the plug in a shrink-fit state

CountermeasureConsider the temperature difference between the gauge and the workpiece. Gauge dimensions are defined at 20 °C[2]

Dents and burrs at the mouth

WhyIt throws off the judgment

CountermeasureCheck the mouth of the part[2]

Inspecting a moving part

WhyDanger of dropping, breakage and flying parts

CountermeasureInspect while it is stopped[2]

Care, storage, inspection and calibration

Care and storage

Inspection and calibration

Taylor's principle: the go side checks the whole form, while the no-go side checks one spot at a time (the name appears in OSG's material).

Related instruments

Frequently asked questions about Plain limit gauge (plug / ring / snap gauge)

What should I check first before measuring with Plain limit gauge (plug / ring / snap gauge)?
Wash the gauge and workpiece with cleaning oil, benzine, etc., or wipe them thoroughly with a clean cloth. Check the gauge for rust, scratches and burrs, and remove them with an oilstone if present Always wipe dust, burrs, and cutting oil from both the measuring faces and the workpiece before taking a reading.
What is the most common mistake when using Plain limit gauge (plug / ring / snap gauge), and how do I prevent it?
Common error: Forcing it through or knocking it out. Scratches, cracks and deformation destroy the gauge's function Countermeasure: If it seizes, tap lightly with a wooden or plastic hammer so the axes line up, or warm the ring side slightly to remove it
How should Plain limit gauge (plug / ring / snap gauge) be cared for, stored, and inspected?
Care and storage: Do not store it fitted to a workpiece or ring (causes sticking and rust) Inspection and calibration: Watch for wear and inspect periodically according to how often it is used. Do not use a gauge beyond its wear limit

Sources

Content without a mark was confirmed by two or more sources from different publishers. Procedures and cautions are summarized in Kezuriba's own words based on the sources, and the figures were drawn by Kezuriba. Accuracy values are manufacturers' published figures unless noted otherwise (values taken from JIS tables are marked as such).

  1. Japanese Standards Association (JSA), "JIS B 7420:1997 Limit plain gauges (bibliographic record)"
  2. OSG, "Technical Data Series No. 2: Thread Gauges (revised May 2016)"